The measuring chamber of the sensor is crossed by infrared radiation. When the air is introduced into this chamber, the molecules of interest absorb a part of the radiation, which reduces the intensity of the optical signal. The concentration of the gas can therefore be deduced according to the Beer-Lambert’s physical law.
NDIR N2O Sensor
NDIR N2O PRO Sensor
Looking for custom gas measurement solutions for your project?
Technical specifications
N2O DETECTION – MODEL NUMBER CO000033
Unit of measurement | ppm |
Measurement range | 0 – 1000 ppm |
Detection limit (3σ) | 200 ppm |
Repeatability | 0.5% Full Scale + 1% reading |
SAMPLING CHARACTERISTICS
Test duration | 4000 ms minimum |
Air inlet | Minimal relative pressure at measuring cell inlet port: 0.3 millibars Maximal relative pressure at measuring cell inlet port: 10 millibars |
Flow rate range | From 0,1 to 1,5 L/min |
Sampling period | 125 ms |
Sample temperature | 34°C +5°C |
Sample humidity | >95% Human breath |
ELECTRICAL CONDITIONS
Supply voltage | 3,7 VDC min 5,5 VDC max |
Input current | 1,5 A max |
Communication interface | RS232 protocol (other on request) Solder pad connection (recommended cable sections : ≤0.13 mm² AWG ≥ 26) |
Discover our evaluation kit to help you pre-integrate and test the sensor in your systems |
ENVIRONMENTAL CONDITIONS
Operating conditions | From 0°C to 50°C |
Storage | From -10°C to 70°C |
Typical starting time | 60s |
PACKAGE INFORMATIONS
Dimensions and weight | 21 x 21 x 80 mm, 17g |
External plastic casing | ABS PC-UL94V0 |
Fixing parts | 3 apertures (Ø 1.6 mm) compatible with self-tapping screws (1.8 mm recommended) to fix OCIEngine |
Sensor architecture
Mechanical drawings
Technical specifications
N2O DETECTION – MODEL NUMBER CO000035 (Test conditions: 23°C, 50%RH, 1013 mbars)
Unit of measurement | ppm |
Measurement range | From 0 to 1000 ppm |
Repeatability (3σ) | 0.5% Full Scale + 1% reading |
Linearity error | 1% reading |
Long term drift (span) | 1% reading |
Pressure effect | 0.05% reading /mbar |
Temperature effect | 0.1% reading / K |
Detection limit (3σ) | 0.5% full scale |
Cross sensitivity (3σ) | Consult manufacturer |
SAMPLING CHARACTERISTICS
Sampling period | 125 ms |
Response time | 2s (τ=63%), at a flow rate of 1 L/min |
Pressure range | Minimal relative pressure at measuring cell inlet port: 0.3 mbar Maximal relative pressure at measuring cell inlet port: 10 mbar |
Flow rate range | From 0,1 to 1,5 L/min |
ENVIRONMENTAL CONDITIONS
Operating conditions | From 0°C to 40°C for breath analysis From -20°C to 70°C for other applications |
Storage | From -20°C to 70°C |
Typical starting time at 23°C | 1 minute (30 minutes at full specifications) |
Humidity | < 100% relative humidity (RH), not condensing |
ELECTRICAL CHARACTERISTICS
Supply voltage | 3,7 VDC min 5,5 VDC max |
Input current | 1,5 A max |
Communication interface | RS232 protocol: Voltage level: ±5,5V ; 3 wires mode x3 Pico-SPOX MOLEX connector (2, 3 and 5 contacts) |
Discover our evaluation kit to help you pre-integrate and test the sensor in your systems |
MECHANICAL CHARACTERISTICS
Dimensions | 125 x 30 x 22mm |
Weight | ~20 g |
External casing | Plastic |
Fixing part | 2 tapped holes for M3 fixing. Length max=5mm |
Sensor architecture
Mechanical drawings
Other related
products
OCIEngine PRO Methane
This sensor is an infrared spectrometer that measures methane in air.
OCIEngine CO2
This sensor is an infrared spectrometer that measures carbon dioxide in exhaled air.
OCIEngine ethanol
This sensor is an infrared spectrometer that measures ethanol in exhaled air.
For any other inquiries, please